A sensitivity study for far infrared balloon-borne limb emission sounding of stratospheric trace gases-
Article in a journal
- | |
|
Area Physics, Atmospheric remote sensing |
Author(s)
J. Xu
, F. Schreier
, P. Vogt
, A. Doicu
, T. Trautmann
|
Published in
Geosci. Instrum. Method. Data Syst. Disc. |
Year 2013 |
Abstract This paper presents a sensitivity study performed for trace gases retrieval from syn- thetic observations by TELIS (TErahertz and submillimeter LImb Sounder) which is a stratospheric balloon-borne cryogenic heterodyne spectrometer. Issues pertaining to hydroxyl radical (OH) retrieval from the far infrared measurements by the 1.8 THz channel are addressed. The study is conducted by a retrieval code PILS (Profile In- version for Limb Sounding) developed to solve the nonlinear inverse problems arising in the analysis of infrared/microwave limb sounding measurements. PILS combines a line-by-line forward model with automatic differentiation for computing Jacobians and employs regularized nonlinear least squares inversion. We examine the application of direct and iterative regularization methods and evaluate the performance of single- and multi-profile retrievals. Sensitivities to expected errors in calibration procedure, instrumental knowledge and atmospheric profiles have been analyzed. Nonlinearity ef- fect, inaccurate sideband ratio, and pointing error turned out to be the dominant error sources. Furthermore, the capability of multi-channel simultaneous retrieval from the far infrared and submillimeter data has been investigated. The errors and averaging kernels infer that the quality of the obtained hydrogen chloride (HCl) can be improved by significantly better exploitation of information from the observations. |
AD Tools TAPENADE |
BibTeX
@ARTICLE{
Xu2013Ass,
author = "J. Xu and F. Schreier and P. Vogt and A. Doicu and T. Trautmann",
title = "A sensitivity study for far infrared balloon-borne limb emission sounding of
stratospheric trace gases",
journal = "Geosci. Instrum. Method. Data Syst. Disc.",
volume = "3",
pages = "251--303",
doi = "http://dx.doi.org/10.5194/gid-3-251-2013",
abstract = "This paper presents a sensitivity study performed for trace gases retrieval from
syn- thetic observations by TELIS (TErahertz and submillimeter LImb Sounder) which is a
stratospheric balloon-borne cryogenic heterodyne spectrometer. Issues pertaining to hydroxyl radical
(OH) retrieval from the far infrared measurements by the 1.8 THz channel are addressed. The study is
conducted by a retrieval code PILS (Profile In- version for Limb Sounding) developed to solve the
nonlinear inverse problems arising in the analysis of infrared/microwave limb sounding measurements.
PILS combines a line-by-line forward model with automatic differentiation for computing Jacobians
and employs regularized nonlinear least squares inversion. We examine the application of direct and
iterative regularization methods and evaluate the performance of single- and multi-profile
retrievals. Sensitivities to expected errors in calibration procedure, instrumental knowledge and
atmospheric profiles have been analyzed. Nonlinearity ef- fect, inaccurate sideband ratio, and
pointing error turned out to be the dominant error sources. Furthermore, the capability of
multi-channel simultaneous retrieval from the far infrared and submillimeter data has been
investigated. The errors and averaging kernels infer that the quality of the obtained hydrogen
chloride (HCl) can be improved by significantly better exploitation of information from the
observations.",
ad_tools = "TAPENADE",
ad_area = "Physics, Atmospheric remote sensing",
year = "2013"
}
| |
back
|
|